cdaq 9178. 0 scans/sec 32 channels ('ai0' - 'ai31. cdaq 9178

 
0 scans/sec 32 channels ('ai0' - 'ai31cdaq 9178  919 809 5227

NI 9205 and NI 9239 analog input modules inserted into a NI cDAQ-9178 acquire the voltage signals from the load cells and the pressure transducer, and the LabVIEW program acquires the current position and velocity of the section model directly from the encoders on the servomotors using Ethernet communication via the MC4U. Figure 1 depicts the schematic diagram of the tactile feedback device. You can find more release information on ni. I am using 2 of the counters to read frequency measurements. Download : Download high-res image (286KB) Download : Download full-size image; Fig. I can't make it works and I've been wondering if the problem comes from me and how I create my program or if the problem is hardware. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements with the higher performance data streaming of USB 3. This article explains which NI C Series modules you can use to access the counters or timers on your CompactDAQ (cDAQ) chassis or controller's backplane. czech@ni. 11-18-2019 11:38 PM. 88 in. The cDAQ‑9179 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. Scenario 2 - I have recently procured new cDAQ - 9178 for new ATE but it is not detecting PXIe but the same works in Host System. Connect the ring lug to the ground terminal on the side of the NI cDAQ-9178 using the ground screw. You can use the NI‑9212 in a variety of applications that are not conducive for bank-isolated channels. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. NI Device Driversは、NI-DAQmx、NI-VISA、NI-SCOPE、NI-SWITCHをはじめ、ほとんどのNI計測器ドライバが含まれているバンドル製品です。. 8. DAQmx is now updated to 9. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. Connect the NI cDAQ-9178 chassis to your host computer. NI Employee (retired) 12-19-2013 04:28 PM. 또한 C 시리즈 I/O 모듈과 외부 호스트 사이의 타이밍,. Visit to learn more about the NI CompactDAQ USB Chassis. Options. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. (a)使用计数器测量占空比. I connected the power cable to the NI 9178. 价格可能因附件和服务的增加而有所不同。. Connect the NI cDAQ-9178 chassis to the system safety ground. 7 and nidaqmx package for python. You can access these counters, as well as share clocks and triggers, through two built-in BNC connectors. 8 or later with the NI-9426 or the NI-9475 and are still seeing the. Ethernet、GPIB、シリアル、USBおよびその他のタイプの計測器をサポートします。. 8 槽 USB CompactDAQ 机箱. The 9178 has 3 separate timing engines. For more information about C Series I/O module power requirements, refer to the documentation for each C Series I/O module. 94 in. 必要な機器: NICompactDAQ. Modules that accept an external master time bases are. If a user wants to generate a 50. Required equipment: NI CompactDAQ chassis The Gen II CompactDAQ chassis support a maximum of two synchronization pulse signals configured for your system. Find many great new & used options and get the best deals for National Instruments CompactDAQ USB Chassis - cDAQ-9178 at the best online prices at eBay! Free. The whole system was first stabilized at 495 °C for three hours. Control a VFD via cDAQ 9178. カスタマイズ可能な. acquired using National Instruments NI cDAQ-9178 chasse module and analog input module NI-9205. When changing the frequency on the front panel, there is a delay where no signal is outputted. 4. In principle this should thus go from 0 to 1 Volt in 1 second. NI cDAQ-9178 섀시 및 NI 9203 Analog Current Input Module. Part Number: 196654C-01L, 781156-01. There is also a Ni-9401 which I can use. This type of ferrite is available from National Instruments (part number 781233-01). It does not include compatibility for CompactRIO Single Board (sbRIO) Controllers. for any updates to the current NI-DAQmx readme. National Instruments cDAQ-9178 8-Slot, USB CompactDAQ Chassis Manuals, Datasheets, Drivers, Links Why can I not communicate with my CompactDAQ (cDAQ) chassis, controller or module in LabVIEW? My cDAQ chassis or controller is missing or not showing up. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. It also controls the timing, synchronisation, and data transfer between C Series I/O modules and an external host. 3 Quick Tips to Fix Code 43 Error: 1. 35 in. cDAQ-9178 è uno chassis CompactDAQ USB progettato per sistemi di misura con sensori portatili, di dimensioni compatte. Use this guide to select the correct power connector for your CompactDAQ Controller or Chassis. NI cDAQ TM-9171/9174/9178 User Manual NI CompactDAQ USB 2. In many cases, you can use multiple options. ) 51. I'm assuming I need a pull down resistor. Connect the Hardware. Fast Quote. AutoPGA sends a set of digital signals, including the sample number expressed as 4-bit data, the start signal, the last sample signal, and the robot control. The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. The data is transferred from the connector to a Python script for automated detection of the fine. You can use this chassis with a combination of C Series I/O modules to create a mix of. FlexLogger does not currently support the built-in PFI lines on the cDAQ chassis, so you will have to use an input on one of your sensor modules as the trigger signal. CompactDAQシステムは、あらゆる距離、あらゆる環境でテスト要件に対応するために必要なデータ検証を収集し、提供します。. 本文主要介绍NI公司图形化编程语言-虚拟仪器LabVIEW软件如何调用NI公司的‍基于C语言的开发环境-LabWindows CVI开发语言生产的(Dynamic Link Library,缩写为 DLL),实现不同开发环境之间LabVIEW和C语言的接口互连,提高不同开发环境之间. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. El cDAQ‑9178 es un chasis USB CompactDAQ diseñado para sistemas pequeños y portátiles de medidas de sensor. The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. Generate output signals by creating a pattern of data that is repeatedly written to the output device. LabVIEW was selected as a readout program because it interfaces well with the NI readout modules. Nach oben. in the NI_DAQmx Task view of your task. 16 in. 0 you can always update to that if you wish to. Solution. Two solutions for getting the chassis to be reserved by the computer are listed below. I tried it anyways and now. When I connect 4 of these sensors to my cDAQ 9178 with using 1 slot of NI 9219, then there is no problem for my VI. This page provides dimensional drawings for the cDAQ-9178. NI PS-14 NI PS-15 NI PS-16 NI PS-17. NIの集録および信号調整デバイスをサポートします。. NI-DAQmx is the software you use to communicate with and control your NI data acquisition (DAQ) device. Launch NI MAX. 7 mm (1. このセクションでは、NI cDAQ-9178 シャーシおよびNI 9401 CシリーズデジタルI / Oモジュールを使用した例を考えます。この手順は別の測定器や測定器を使用する場合も同様です。 図8. ; Click on Create Task. 8‑Slot, USB CompactDAQ Chassis. . Scenario 2 - I have recently procured new cDAQ - 9178 for new ATE but it is not detecting PXIe but the same works in Host System. NI Employee (retired) 10-10-2011 11:33 AM. Connect the power source to the NI cDAQ-9178 chassis. Lo chassis offre la semplicità plug-and-play della tecnologia USB per misure elettriche e con sensore. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. Pricing and Availability on millions of electronic components from Digi-Key Electronics. Find the heading titled Universal Serial Bus controllers and expand it. All singles are processed by the LabVIEW data acquisition system, which consists of an industrial computer, a NI cDAQ-9178 data acquisition board, two NI 9213 modules to obtain temperature and four NI 9203 modules to obtain current signals of pressure transducers. The experimental set-up and acquisition system used can be seen in Fig. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. El chasis brinda la sencillez de conexión rápida (plug‑and‑play) del USB a sus medidas eléctricas y de sensores. 以下のビデオをご覧いただき、手順に従ってください。. NI-XNET is an NI instrument driver that features a common set of easy-to-use functions for reading and writing Automotive Ethernet, CAN, LIN, and FlexRay data on many different platforms including USB, PXI, PCI, NI CompactDAQ, and NI CompactRIO. e. ) 59. 0 out of 5 stars based on 1 product rating. You can find more release information on ni. Starten Sie den Computer neu, wenn Sie dazu aufgefordert werden. Options. On the right-hand panel, navigate to My System >> Devices and Interfaces and right-click a device. 2 are used to read data from ultrasonicsI am attempting to switch a system running on Windows XP to a Windows 64 bit computer. The minimum sample rate for the NI-9234 depends on the master timebase. Hi, Yes, you can import triggers and a sample clock into a cDAQ-9178 over the two PFI lines. When we go through the My Computer->Device Manager window, we could see USB Flash Firmware Updater as. The major concern is latency, not signal integrity, which is why your extension cable only works for slower sampling rates. It also controls the timing, synchronization, and data transfer between C Series I/O. com de dos maneras: Correo electrónico de reclamación de software: Después de comprar LabVIEW u otros módulos. Each chassis must have one NI-9469 to be installed, so two NI-9469 are required in this case. b) Connect the ring lug to the ground terminal on the side of the NI cDAQ-9178 using the ground screw. Descargue LabVIEW Los clientes pueden tener acceso a las descargas de software de ni. 修理、RMA、キャリブレーション予定. 3. 開発用コンピュータにLabVIEWがインストールされ、アクティブ化されたので、次にハードウェアを接続します。. I got an analog input module NI 9201,analog output module NI 9263 and digital output module NI 9472. Go to " Help » Find Examples. NI-DAQmx Issue Details When I connect my USB DAQ or CompactDAQ (cDAQ) device to my computer, Windows recognizes that new hardware was found. The solenoid valve was also powered directly by 110 V AC with an integrated switch for remote operation. #LearnLabview#LearnElectronic#learnProgramming#futureTechnologyTwo NI cDAQ-9178 8-slot chassis, synchronized via NI 9469, with multiples of following modules; NI 9237 – Bridge Analog Input NI 9205 – 250 kS/s Analog Input NI 9207 – Voltage/Current Analog Input NI 9485 – SSR Relay NI 9234 – IEPE and AC/DC Analog Input Industry Transportation and Heavy Equipment Application Area200 kS/s, ±20 mA, 8-Channel C Series Current Input Module The NI‑9203 is intended for high-performance control and monitoring applications. 4. An eddy-current brake, capable of measuring the torque and the power of internal combustion engines at desired rotational speeds, has been fully interfaced with an external NI cDAQ 9178 data logger. Equipo requerido: Chasis NI CompactDAQObtain the IP address of the ethernet cDAQ chassis and ensure you are connected to network that can reach the hardware itself. (RS-232 only) A cDAQ-913x controller, such as the cDAQ-9137 have a RS-232 port on the device. The cDAQ-9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. When I go to MAX (Measurement & Automation Explorer) and go to the "Devices and Interfaces", and I press F5 (Refresh), it can not detect NI 9178. NI-DAQmx Issue Details When I connect my USB DAQ or CompactDAQ (cDAQ) device to my computer, Windows recognizes that new hardware was found. Description. 8 mm (1. If you are using the NI cDAQ-9178 chassis PFI trigger lines, you should install a ferrite with an impedance of 275 Ω at 100 MHz on each BNC trigger cable used. The RDE was controlled using a RDE710 Rotating Electrode setup from Gamry Instruments. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. This CompactDAQ also controls the planning, synchronization, and. 02-01-2023 03:55 PM. 低周波数信号の場合、使用するカウンタまたは内部タイムベースは1つで十分です。. All experiments were carried out in a temperature-controlled room (20 ± 0. It will also help if you see a red X next to where you had been able to see your cDAQ previously, or if you can't add your module to your network cDAQ chassis in NI MAX. Free shipping. The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. Power Supply Part Number: 190415B-01. cDAQ 9178 CompactDAQ chassis. 12-13-2016 06:58 AM. Using a custom master timebase,you can achieve rates below this. 7 mm (2. NI GPIBコントローラおよびGPIBポートを備えたNI組込コントローラをサポートします。. The estimation particulars, including number of channels, channel setup, test rate, and pick up, are dictated. 47 in. Power Supply CompactDAQ Controller Accessory Compatibility Tables. Sensors are connected by means of coaxial cables with BNC connectors to three 4-channels dynamic signal acquisition module NI-9234 characterized by measurement range of 0. A National Instrument NI cDAQ-9178 was used as the data acquisition system. PDF DXF 3D CAD Models. This is significant because with this device you are able to acquire data at different rates at the same time. El cDAQ-9178 es un chasis USB CompactDAQ diseñado para sistemas de medición de sensores pequeños y portátiles. El chasis proporciona la simplicidad plug-and-play de USB a sensores y mediciones eléctricas. NI-DAQmx Manuals: New features, behavior changes, and other documentation. You can use this chassis with. cDAQ-9178은 소형, 휴대용 센서 측정 시스템을 위해 설계된 CompactDAQ USB 섀시입니다. コミュニティ. The cDAQ-9178 power supply. 2. 2. In addition, the digital encoder waveforms from the servo motor were captured by a NI-9361 8 channel digital input module. Triggering problem on cDAQ-9178. 2770-781156-01-ND. Task » Hardware Input and Output » DAQmx » Analog Input ». 机箱通过即插即用的USB可轻松连接传感器和电气测量。. When I look in the Windows Device Manager, the device has a yellow exclamation point and says USB Flash Firmware Loader. 0mm EMI Suppression Ferrites can be used to suppress EMI for BNC cabling to NI-DAQmx driver software is. Recommended Equipment Equipment. Using incompatible versions may result in errors, missing LabVIEW palettes or functions,. You can use this chassis with a combination of C Series I/O modules to create a mix of. A virtual channel is a collection of settings such as a name, a physical channel, input terminal connections, the type of measurement or generation, and can include scaling information. 08-28-2022 06:49 PM. What are the subVIs and function blocks that will allow me to program my cDAQ?NI cDAQTM-9171/9174/9178 User Manual NI CompactDAQ USB 2. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. (this is NI cDAQ 9178 plugged via USB on a Windows 10 computer, and with the NI 9264 output module wired to a multimeter so that I can check the output changing) # Continuous write single channel. comThe signals were captured with a National Instruments® NI cDAQ-9178 data acquisition system (DAQ), equipped with an NI 9223 module to capture signals with a sampling rate of 51,2 kS/s. com I and Ins trumenta tion o r industry Resumen del producto. cdaq-9178 シャーシには 4 つのオンボードカウンタがあります。デジタルモジュール(例えばni 9401 または ni 9402)を接続せずにカウンタタスクを実行したいですが、物理チャンネルにリストされず、1つのオンボードカウンタにもアクセスできません。 4つのカウンタチャンネルにデジタル. Check the module datasheet to ensure that these modules allow synchronization. This acquisition system is used in the sine sweep mode and an average over 300 cycles is used at each frequency step. Pair sensor-specific, conditioned I/O modules with software optimized for DAQ applications. NI Employee (retired) 12-19-2013 04:28 PM. The fluorescence signals in addition to TTL signals from behavioral settings were digitized by a data acquisition module (cDAQ-9178, National Instruments), and simultaneously recorded using a. ) INPUT 9-30 V 15 W MAX POWER READY ACTIVE V C TRIG 0 TRIG 1 47. Please note that while the 2D dimensional drawings are available for most parts numbers, the 3D models are not. to verify your subscription or service agreement is valid. 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module. Align the C Series module with the CompactDAQ chassis slot and insert the module. Contact us with questions for pricing. Touch position can be determined by comparing the amplitudes of the signal. 01-21-2021 08:38 AM. 0 Chassis NI cDAQ-9171/9174/9178 User Manual July 2016 372838E-01The cDAQ‑9171 is a bus‑powered, CompactDAQ USB chassis designed for small, portable sensor measurement systems. Provides support for NI data acquisition and signal. National Instruments 781156-01 CompactDAQ Chassis. cDAQ comes in two main flavors: with a controller, and without a controller. An AU02 torque hammer with an AC21 force sensor is also connected to the analog input module. com. Why can I not communicate with my CompactDAQ (cDAQ) chassis, controller or module in LabVIEW? My cDAQ chassis or controller is missing or not showing up. Options. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. The thin dotted line in Fig. From the NI 9411 pinout diagram (see pdf file attached to this post), these are the connections I made: CTR 0 SRC, pin 1 to COM/ground. NI's CompactDAQ Chassis has options for one to 14 module slots, allowing users to choose the I/O modules needed for their current and future test applications. For that: In Windows Device Manager, right-click on the device, and select Update Driver Software. Durante este proceso, instalará y activará el siguiente software y controladores en su PC de desarrollo: LabVIEW. This file contains installation instructions and compatibility information for NI-DAQmx. It does not explicitly cover other NI. 2 °C). Capture a Unique Event in Incoming Data. Member. This behavior is caused by the Ethernet cDAQ chassis not being automatically reserved by the computer. Some CompactDAQ chassis can be connected using Ethernet. Als Nächstes geht es darum, wie die CompactDAQ-Hardware verbunden wird. Thanks in. Digi-Key Part Number. Main characteristics of the test engine. Dan_N. 50An impulse excitation was applied to the milling tool tip using an impact hammer (PCB 086D05) in directions collinear with the X, Y, and Z axes of the sensor. 0. om Ema il: ales@a li con. It also controls the timing, synchronisation, and data transfer between C Series I/O modules and an external host. Click Create Task. Sensor data was recorded on a computer through a specific program developed in LabVIEW (National Instruments, USA). 1 mm (0. The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. これらは、ネットワーク全体で計測を同期できるデータ収集モジュールで構成されています。. It also helps you control the timing, synchronization, and data transfer between C Series I/O modules and an. Connect the CompactDAQ system to the development computer using the USB cable. I connected the USB cable to the PC. This. Connect the NI cDAQ-9178 chassis to your host computer. Data Availability. また、質問を投稿することもできます。. Experimental condition. Options. 如果上一部分出现“检测到的设备” (Device Detected)窗口,则通过该窗口启动。. 2. Begin learning data acquisition by acquiring a signal from a microphone and outputting a signal to illuminate an LED. In a cRIO, for example, the POWER LED should be solid green. 43 in. Also, 6 test sections. Insert a thin, flat screwdriver into the square hole adjacent to the circular hole you wish to use. The chassis is equipped with modules for thermocouple measurements (NI-9214), RTD measurement (NI-9217), and for measuring the voltage drop across the. The NI cDAQ-9178 (eight slots) and NI cDAQ-9174 (four slots) USB chassis are designed for use with C Series I/O modules. Step 2: Connect the USB cord to number 1 above. NI-DAQmx Release Notes: Known issues, bugs fixed since the last release, and other notes about this release. Discover Devices that Support Accelerometers. The data acquisition system used in this experiment, shown in Fig. Connect the NI cDAQ-9178 chassis to your host computer. Learn how to install, configure, and acquire data from your NI CompactDAQ USB. Re: Power for NI 9862 within cDAQ 9178. changed the computer with windows 10 64 bit . In terms of specifications, the two cDAQ chassis should have almost exactly the same specs (at least in all the ways that would affect that connection) -- the only main difference is the number of modules, as you mentioned. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. when connected to the USB 2 port, a beep is generated in Windows, along with a notification that the USB Device Not Recognized. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. 1 shows the schematic of the RCM experimental setup. A valid service agreement may be required. Only 6 of the 8 slots of the cDAQ are used, therefore the power. g. NI-DAQmx 19. . Connect the NI cDAQ-9178 chassis to your host computer. Ethernet、GPIB、シリアル、USBおよびその他のタイプの計測器をサポートします。. Contact us with questions for pricing. NI-DAQmx provides multiple functions for reading and writing data. また、利用可能なすべてのエディションは、このダウンロードページから. This will change all the network configuration settings to default. 2] and thermocouples (symbol Ⓣ in Fig. Ltd, Beijing) and iso -octane (99. The detail experimental set-up with necessary components is described in Fig. Description Instead one of the 2 onboard PFI lines will be routed to the onboard counter. You can use this chassis with. ステップ3. cDAQ-9178, not shown in Fig. 4 mm (1. Member. Ultra-high purity grade oxygen, nitrogen, argon (>99. NI cDAQ-9178 Specifications These specifications are for the National Instruments CompactDAQ 9178 chassis only. NI-DAQmx is the software you use to communicate with and control your NI data acquisition (DAQ) device. The Data Acquisition system (NI-cDAQ-9178) was used to record the temperature and pressure data during the experiment. 3 Readme. The cDAQ-9178, 9179, 9188 and 9188XT have two built-in PFI lines, so if no more than two trigger lines will be required, there is no need for a digital module. Hi! I want to control a Variable frequency driver through the cDAQ-9178. CompactDAQ is a cost-effective approach to benchtop measurement. A programmable power source (Koard KA3005P) powers the heater. Stability of room temperature was first assured before starting any experiment. item 2 National Instruments NI cDAQ-9178 FREE SHIP National Instruments NI cDAQ-9178 FREE SHIP. CTR 1 SRC, pin 6 to COM/ground. cDAQ-9178製品 の 規格 認証 - NI ホームページに戻る Re: Want to reset CDAQ-9178 chassis via my C# program, Ryan_K. The cDAQ-9174 CompactDAQ Chassis (Part Number: 781157-01) has four slots, which can each hold a C Series module. . cDAQ-9178. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. 指定的采样率必须是源的一个除数。. I mean to say The cDAQ is detected but when i connect the module to it then that module is not detected. Download : Download high-res image (515KB) Download : Download full-size image; Fig. El chasis proporciona la simplicidad plug-and-play de USB a sensores y mediciones eléctricas. 2. The T60 UV-visible spectrophotometer and the NI cDAQ – 9178 were used to measure the optical transmittance and the sheet resistance of the Cu NW electrode, respectively. Reference this information to ensure you install the correct version when upgrading or updating your system or software. If a known pressure is applied to any channel, I get 5V If the same pressure is applied to 2 channels, I get 2. cDAQ-9178 chassis, NI 1913 thermocouple module input and an NI 9219 universal analog input module for measuring voltage and current. Many teams struggle to manage product quality within shorter and shorter time-to-market windows, but best-in-class test organizations are leading the way. National Instrument NI cDAQ-9178 Manual Start DAQExpress: Step 1: Turn on the system by connecting to an outlet using output number 4 above. 4. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. Controlla anche la temporizzazione, la sincronizzazione e il trasferimento dati tra moduli I/O C Series e un host esterno. You can use this chassis with. The drivers for this device are not installed. In a CompactDAQ system, a chassis is connected to your PC through USB or Ethernet, and then populated with one or more conditioned I/O modules for direct sensor connectivity. 0 Host. The cDAQ-9189, has one buit-in PFI, that can be used for this purpose. NI-DAQmx. MiguelCSUN. Important Notice: Other accessories, manuals, cables,. cDAQ-9178 Product Certifications. Member. In this platform, the chassis was connected to the C-series acquisition cards NI 9203, NI 9211 and NI 9201 through a high-speed internal bus, and supplied power to the module to. Leave slots 1 through 7 of the NI cDAQ-9178 chassis empty. Use this article if you want to use a quadrature encoder or other sensor to measure frequency, period, pulse width, semi period, two edge. To verify the proposed design criteria, an open-circuit small-scale wind tunnel was built and tested. デジタル周波数を収集するプロセスは極めて簡単です。. The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. Ensure that power is disconnected from the CompactDAQ chassis. Order by Part Number or Request a Quote. I left it plugged in for 10 or 15 minutes while doing other things, and the chassis eventually detected on its own. 8 mm (1. 0 has the following requirements: 1 GHz or faster 32-bit (x86) or 64-bit (x64) processor. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. Step 3. Scenario 1 - I have one cDAQ - 9178 and it works perfectly fine in one of our ATE (Automated Test Equipment). 2 kS/s/ch, mounted on 8-slot USB chassis NI cDAQ 9178. The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. Has usb, ethernet, or wifi, mult slots to account for i/o for variouse applications. 4 upstream stagnation pressures were selected. I think the solution for me will be to disconnecting the power suppy cable from the cDAQ and reconnect it to the cDAQ and the NI9862 in parallel. NI cDAQTM-9171/9174/9178 User Manual NI CompactDAQ USB 2.